Alerting that only pages for real problems
Page on symptoms that threaten the SLO, use burn-rate alerts, and route everything else to a ticket.
15 min readThe cost of noise
Every page wakes someone up and interrupts deep work. If half of a rotation's pages need no action, engineers learn to acknowledge without looking, and the real incident is missed. A healthy target is fewer than two pages per on-call shift, each one actionable and urgent. Every page should answer three questions in its text: what users are experiencing, how bad it is, and where the runbook is. Alerts that fail that test should be downgraded to tickets or deleted.
Symptoms, not causes
Page on symptoms users feel, such as error rate or latency SLIs, not on causes such as high CPU or one dead instance. A host at 95% CPU that serves requests fine is not an emergency, and a fleet that autoscaled around a dead instance needs no human at 3 a.m. Cause-based signals still matter: they belong on dashboards and in tickets, where they help diagnose the symptom alert when it does fire. The exception is a cause that predicts certain user impact before symptoms appear, such as a disk that will be full in two hours; that deserves a page because waiting for the symptom means an outage.
- Page: SLO burn, total outage of a critical journey, data loss risk
- Ticket: disk 80% full in 5 days, certificate expiring in 14 days, single replica down
- Dashboard only: CPU, GC pauses, cache hit rate
Burn-rate alerts
A burn rate is how fast you are spending the error budget relative to plan. A burn rate of 1 exactly uses the budget over the 30-day window; a burn rate of 14.4 uses 2% of a monthly budget in one hour. The widely used multiwindow approach pages when the one-hour burn rate exceeds 14.4 and the five-minute rate confirms it is still happening, and opens a ticket when the six-hour rate exceeds 6 or the three-day rate exceeds 1. This catches fast outages within minutes and slow leaks within hours, without paging on a 30-second blip.
Routing and hygiene
Alerts need owners. Route by service ownership, deduplicate alerts that share a root cause (one database outage should not fire forty service alerts), and silence downstream alerts while a known incident is open. Review alerts monthly: anything that fired without action is a candidate for deletion. In SystCode, an uptime monitor or monitoring component on your canvas shows that a design has a detection path; the challenges check that failures are noticed, not just survived. Monitors should also run from outside your own infrastructure, so an outage that takes down your network does not take down the alerting with it.
Key takeaways
- Every page must be urgent, actionable and tied to user impact
- Page on SLO burn rate, not on resource thresholds
- Multiwindow burn-rate alerts catch both fast outages and slow leaks
- Delete or downgrade any alert that repeatedly fires without action
Sign in to track lessons and earn badges.